www.vishay.com For technical questions, contact: filmresistors.leaded@vishay.com Document Number: 28722
40 Revision: 20-Feb-08
SFR16S/25/25H
Vishay BCcomponents Standard Metal Film Resistors
TESTS AND REQUIREMENTS
Essentially all tests are carried out in accordance with the
schedule of “IEC publication 60115-1”, category 55/155/56
(rated temperature range - 55 °C to + 155 °C; damp heat,
long term, 56 days). The testing also covers the
requirements specified by EIA and EIAJ.
The tests are carried out in accordance with IEC publication
60068-2, “Recommended basic climatic and mechanical
robustness testing procedure for electronic components” and
under standard atmospheric conditions according to
“IEC 60068-1”, subclause 5.3.
In the Test Procedures and Requirements table the tests and
requirements are listed with reference to the relevant clauses
of “IEC publications 60115-1 and 60068-2”; a short
description of the test procedure is also given. In some
instances deviations from the IEC recommendations were
necessary for our method of specifying.
TEST PROCEDURES AND REQUIREMENTS
IEC
60115-1
CLAUSE
IEC
60068-2
TEST
METHOD
TEST PROCEDURE
RESISTANCE
RANGE
REQUIREMENTS
SFR16S SFR25 SFR25H
4.16 21 (U) robustness of
terminations:
4.16.2 21 (Ua1) tensile all samples
Ø 0.45 mm, load 5 N; 10 s
number of failures < 10 x 10-6
Ø 0.58 mm, load 10 N; 10 s
4.16.3 21 (Ub) bending half
number of samples
Ø 0.45 mm, load 2.5 N; 4 x 90°
number of failures < 10 x 10-6
Ø 0.58 mm, load 5 N; 4 x 90°
4.16.4 21 (Uc) torsion other half of
samples 3 x 360° in opposite directions no damage
ΔR max.: ± (0.25 % R + 0.05 Ω)
4.17 20 (Ta) solderability 2 s; 235 °C; flux 600 good tinning; no damage
4.18 20 (Tb) resistance to
soldering heat
3.5 seconds; 350 °C;
solder bath method ΔR max.: ± (0.25 % R + 0.05 Ω)
4.19 14 (Na) rapid change of
temperature
30 min at - 55 °C and
30 min at + 155 °C; 5 cycles ΔR max.: ± (0.25 % R + 0.05 Ω)
4.20 29 (Eb) bump 3 x 1500 bumps in 3 directions;
40 g
no damage
ΔR max.: ± (0.25 % R + 0.05 Ω)
4.22 6 (Fc) vibration
Frequency 10 Hz to 500 Hz;
displacement 1.5 mm or
acceleration 10 g; 3 directions;
total 6 h (3 x 2 h)
no damage
ΔR max.: ± (0.25 % R + 0.05 Ω)
4.23
climatic sequence
:Rins min.: 1000 MΩ
4.23.2 2 (Ba) dry heat 16 h; 155 °C
4.23.3 30 (Db)
damp heat
(accelerated)
1st cycle
24 h; 55 °C;
90 % to 100 % RH
4.23.4 1 (Aa) cold 2 h; - 55 °C
4.23.5 13 (M) low air pressure 2 h; 8.5 kPa; 15 °C to 35 °C
4.23.6 30 (Db)
damp heat
(accelerated)
remaining cycles
5days; 55°C;
95 % to 100 % RH
R≤1MΩΔR max.: ± (1 % R + 0.05 Ω)
R>1MΩΔR max.: ± (1 % R + 0.05 Ω)ΔR max.
± (2 % R +0.1
4.24.2 3 (Ca) damp heat
(steady state)
56 days; 40 °C;
90 % to 95 % RH;
dissipation 0.01 Pn
Rins min.: 1000 MΩ
ΔR max.: ± (2 % R + 0.05 Ω)