Spec-00069 M
CABLE PATHWAY / BONDING AND GROUNDING Cable Pathway and aCCessories
PH 763.422.2661 • FAX 763.422.2588 • HOFFMANONLINE.COMEQUIPMENT PROTECTION NETWORKING 2
LADDER RACK STRAIGHT SECTIONS (CULUS CLASSIFIED)
Supports cable on straight runs.
Made of 1-1/2 in. x 3/8 in. (38 mm x
8 mm) 16 gauge tubular steel with
a painted or plated finish. Nominal
installed length is 10 ft. (3.05 m).
Each section is 9 ft. 11-1/2 in. (3.03
m) long with cross members welded
at 9-in. (229-mm) intervals.
Bulletin: DcR
Catalog Number Finish W (in.) W (mm)
LSS6G Gray 6.00 152
LSS6BLK Black 6.00 152
LSS6GZ Plated 6.00 152
LSS12G Gray 12.00 305
LSS12BLK Black 12.00 305
LSS12GZ Plated 12.00 305
LSS18G Gray 18.00 457
LSS18BLK Black 18.00 457
LSS18GZ Plated 18.00 457
LSS24BLK Black 24.00 610
LADDER RACK CURVED SECTIONS (CULUS CLASSIFIED)
Provide a vertical change in
direction. They are made of 1-1/2
in. x 3/8 in. (38 mm x 8 mm) tubular
steel with a painted or plated finish.
Cross members are welded on the
inside (inside bends) or outside
(outside bends) of the section.
Connect to straight section with
butt-splice kits. Designed for
category 5e, 6, 6A and fiber optic
cable.
Bulletin: DcR
Catalog Number Finish Vertical Bend Type W (in.) W (mm)
LIB6G Gray Inside 6.00 152
LIB6BLK Black Inside 6.00 152
LIB6GZ Plated Inside 6.00 152
LIB12G Gray Inside 12.00 305
LIB12BLK Black Inside 12.00 305
LIB12GZ Plated Inside 12.00 305
LIB18G Gray Inside 18.00 457
LIB18BLK Black Inside 18.00 457
LIB18GZ Plated Inside 18.00 457
LIB24BLK Black Inside 24.00 610
LOB6G Gray Outside 6.00 152
LOB6BLK Black Outside 6.00 152
LOB6GZ Plated Outside 6.00 152
LOB12G Gray Outside 12.00 305
LOB12BLK Black Outside 12.00 305
LOB12GZ Plated Outside 12.00 305
LOB18G Gray Outside 18.00 457
LOB18BLK Black Outside 18.00 457
LOB18GZ Plated Outside 18.00 457
LOB24BLK Black Outside 24.00 610
90DEGREE HORIZONTAL EBEND SECTION (CULUS CLASSIFIED)
Provide a 90-degree horizontal
change in cable runway direction.
Made of 1-1/2 in. x 3/8 in. (38 mm x
8 mm) tubular steel with a painted
or plated finish. Connect to straight
sections with butt-splice kits.
Designed for category 5e, 6, 6A and
fiber optic cable.
Bulletin: DcR
Catalog Number Finish W (in.) W (mm)
L90HB12G Gray 12.00 305
L90HB12BLK Black 12.00 305
L90HB12GZ Plated 12.00 305
L90HB18G Gray 18.00 457
L90HB18BLK Black 18.00 457
L90HB18GZ Plated 18.00 457
L90HB24BLK Black 24.00 610
BUTTSPLICE KIT (CULUS CLASSIFIED)
Joins straight ladder rack sections,
inside and outside bends, and
90-degree horizontal e-bends. Each
kit connects one section to another.
Includes mounting hardware.
Bulletin: DcR
Catalog Number Finish Kit Qty.
LBSKG Gray 2
LBSKB Black 2
LBSK Plated 2
ADJUSTABLE BUTTSPLICE KIT (CULUS CLASSIFIED)
Provides a change in up-and-down
direction of the cable runway. It
can be adjusted to any angle from
0 to 90 degrees. Made of steel with
a painted or plated finish. Each kit
connects one ladder rack section
to another. Includes mounting
hardware.
Bulletin: DcR
Catalog Number Finish Kit Qty.
LABSKG Gray 2
LABSKB Black 2
LABSK Plated 2