Product data sheet Characteristics ATV212HD22N4S variable speed drive ATV212 - 22kW - 30hp 480V - 3ph - EMC - IP21 Range of product Altivar 212 Product or component type Variable speed drive Device short name ATV212 Product destination Asynchronous motors Product specific application Pumps and fans in HVAC Assembly style With heat sink Network number of phases 3 phases Motor power kW 22 kW Motor power hp 30 hp Power supply voltage 380...480 V (- 15...10 %) Power supply voltage limits 323...528 V Supply frequency 50...60 Hz (- 5...5 %) Network frequency 47.5...63 Hz EMC filter Class C2 EMC filter integrated Line current 32.6 A for 480 V 41.1 A for 380 V Complementary Apparent power 27.3 kVA for 380 V Prospective line Isc 22 kA Continuous output current 43.5 A at 380/460 V Maximum transient current 47.9 A for 60 s Speed drive output frequency 0.5...200 Hz Nominal switching frequency 8 kHz Switching frequency 8...16 kHz with derating factor 6...16 kHz adjustable Speed range 1...10 Speed accuracy +/- 10 % of nominal slip for 0.2 Tn to Tn torque variation Torque accuracy +/- 15 % Transient overtorque 120 % of nominal motor torque, +/- 10 % for 60 s Asynchronous motor control profile Voltage/Frequency ratio, 2 points Voltage/Frequency ratio, 5 points Flux vector control without sensor, standard Voltage/Frequency ratio - Energy Saving, quadratic U/f Voltage/Frequency ratio, automatic IR compensation (U/f + automatic Uo) Regulation loop Adjustable PI regulator Motor slip compensation Adjustable Automatic whatever the load Not available in voltage/frequency ratio motor control Local signalling 1 LED - red - DC bus energized Output voltage <= power supply voltage Isolation Electrical between power and control Type of cable for external connection UL 508 cable with UL Type 1 kit: 3 wire(s) - 40 C, copper 75 C / PVC IEC cable without mounting kit: 1 wire(s) - 45 C, copper 70 C / PVC IEC cable without mounting kit: 1 wire(s) - 45 C, copper 90 C / XLPE/EPR Electrical connection Terminal 25 mm / AWG 3 (L1/R, L2/S, L3/T) Terminal 2.5 mm / AWG 14 (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) Nov 25, 2014 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Main Tightening torque 4.5 N.m - 40 lb.in (L1/R, L2/S, L3/T) 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) Supply Internal supply: 24 V (21...27 V) DC - <= 200 A with overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC, +/- 5 % <= 10 A with overload and short-circuit protection Analogue input number 2 Analogue input type Configurable voltage: (VIB) 0...10 V DC - 24 V max - 30000 Ohm - resolution: 10 bits Switch-configurable current: (VIA) 0...20 mA - 250 Ohm - resolution: 10 bits Switch-configurable voltage: (VIA) 0...10 V DC - 24 V max - 30000 Ohm - resolution: 10 bits Configurable PTC probe: (VIB) 0...6 probes - 1500 Ohm Sampling duration 22 ms +/- 0.5 ms (VIB) - analog input(s) 3.5 ms +/- 0.5 ms (VIA) - analog input(s) 2 ms +/- 0.5 ms (RES) - discrete input(s) 2 ms +/- 0.5 ms (R) - discrete input(s) 2 ms +/- 0.5 ms (F) - discrete input(s) Response time 7 ms +/- 0.5 ms (RY, RC) - discrete output(s) 7 ms +/- 0.5 ms (FLB, FLC) - discrete output(s) 7 ms +/- 0.5 ms (FLA, FLC) - discrete output(s) 2 ms +/- 0.5 ms (FM) - analog output(s) Accuracy +/- 1 % (FM) for a temperature variation 60 C +/- 0.6 % (VIB) for a temperature variation 60 C +/- 0.6 % (VIA) for a temperature variation 60 C Linearity error +/- 0.2 % for output (FM) +/- 0.15 % of maximum value for input (VIB) +/- 0.15 % of maximum value for input (VIA) Analogue output number 1 Analogue output type Switch-configurable current: (FM) 0...20 mA - 970 Ohm - resolution: 10 bits Switch-configurable voltage: (FM) 0...10 V DC - 7620 Ohm - resolution: 10 bits Discrete output number 2 Discrete output type Configurable relay logic: (RY, RC) NO - 100000 cycles Configurable relay logic: (FLB, FLC) NC - 100000 cycles Configurable relay logic: (FLA, FLC) NO - 100000 cycles Minimum switching current 3 mA at 24 V DC (configurable relay logic) Maximum switching current 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) Discrete input type Programmable (RES) 24 V DC, with level 1 PLC - 4700 Ohm Programmable (R) 24 V DC, with level 1 PLC - 4700 Ohm Programmable (F) 24 V DC, with level 1 PLC - 4700 Ohm Discrete input logic Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1) Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1) Acceleration and deceleration ramps Automatic based on the load Linear adjustable separately from 0.01 to 3200 s Braking to standstill By DC injection Protection type With PTC probes for motor Motor phase break for motor Thermal protection for motor Against input phase loss for drive Line supply undervoltage for drive Line supply overvoltage and undervoltage for drive Against exceeding limit speed for drive Break on the control circuit for drive Overvoltages on the DC bus for drive Overcurrent between output phases and earth for drive Input phase breaks for drive Short-circuit between motor phases for drive Thermal power stage for drive Overheating protection for drive Dielectric strength 5092 V DC between control and power terminals 3535 V DC between earth and power terminals Insulation resistance >= 1 MOhm at 500 V DC for 1 minute Frequency resolution 0.024/50 Hz for analog input 0.1 Hz for display unit 2 Communication port protocol APOGEE FLN BACnet LonWorks METASYS N2 Modbus Connector type 1 RJ45 1 open style Physical interface 2-wire RS 485 Transmission frame RTU Transmission rate 9600 bps or 19200 bps Data format 8 bits, 1 stop, odd even or no configurable parity Type of polarization No impedance Number of addresses 1...247 Communication service Monitoring inhibitable Read device identification (43) Read holding registers (03) 2 words maximum Time out setting from 0.1 to 100 s Write multiple registers (16) 2 words maximum Write single register (06) Option card Communication card for LonWorks Operating position Vertical +/- 10 degree Width 245 mm Height 330 mm Depth 190 mm Product weight 11.65 kg Power dissipation in W 723 W Fan flow rate 214 m3/h Environment Electromagnetic compatibility Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 1.2/50 s - 8/20 s surge immunity test level 3 conforming to IEC 61000-4-5 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Pollution degree 3 IEC 61800-5-1 IP degree of protection IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529 IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1 IP41 on upper part conforming to EN/IEC 60529 IP41 on upper part conforming to EN/IEC 61800-5-1 IP21 conforming to EN/IEC 60529 IP21 conforming to EN/IEC 61800-5-1 Vibration resistance 1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-8 1.5 mm (f = 3...13 Hz) conforming to EN/IEC 60068-2-6 Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27 Environmental characteristic Classes 3S2 conforming to IEC 60721-3-3 Classes 3C1 conforming to IEC 60721-3-3 Noise level 59.9 dB conforming to 86/188/EEC Operating altitude 1000...3000 m (limited to 2000 m for the Corner Grounded distribution network) with current derating 1 % per 100 m <= 1000 m without derating Relative humidity 5...95 % without dripping water conforming to IEC 60068-2-3 5...95 % without condensation conforming to IEC 60068-2-3 Ambient air temperature for operation > 40...50 C with derating factor -10...40 C without derating Ambient air temperature for storage -25...70 C 3 Standards EN 55011 class A group 1 EN 61800-3 EN 61800-3 category C2 EN 61800-3 category C3 EN 61800-3 environments 1 category C1 EN 61800-3 environments 1 category C2 EN 61800-3 environments 1 category C3 EN 61800-3 environments 2 category C1 EN 61800-3 environments 2 category C2 EN 61800-3 environments 2 category C3 EN 61800-5-1 IEC 61800-3 IEC 61800-3 category C2 IEC 61800-3 category C3 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C3 IEC 61800-5-1 UL Type 1 Product certifications CSA C-Tick NOM 117 UL Marking CE 4 Product data sheet Dimensions Drawings ATV212HD22N4S Dimensions Plate for EMC mounting (supplied with the drive) (1) 2 x M5 screws 5 Product data sheet Mounting and Clearance ATV212HD22N4S Mounting Recommendations Clearance Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate accessories. Install the unit vertically: Do not place it close to heating elements. Leave sufficient free space to ensure that the air required for cooling purposes can circulate from bottom to the top of the unit. Mounting Types Type A mounting Type B mounting Type C mounting By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP21. The protective blanking cover may vary according to the drive model, see opposite. Specific Recommendations for Mounting in an Enclosure To help ensure proper air circulation in the drive: Fit ventilation grilles. Check that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must provide a flow rate at least equal to that of the drive fans (refer to the product characteristics). Use special filters with UL Type 12/IP54 protection. Remove the blanking cover from the top of the drive. 6 Sealed Metal Enclosure (IP54 Degree of Protection) The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions, such as dust, corrosive gases, high humidity with risk of condensation and dripping water, splashing liquid, etc.This enables the drive to be used in an enclosure where the maximum internal temperature reaches 50C. 7 Product data sheet Connections and Schema ATV212HD22N4S Recommended Wiring Diagram 3-Phase Power Supply A1: ATV 212 drive KM1: Contactor Q1: Circuit breaker Q2: GV2 L rated at twice the nominal primary current of T1 Q3: GB2CB05 S1, XB4 B or XB5 A pushbuttons S2: T1: 100 VA transformer 220 V secondary (1) Fault relay contacts for remote signalling of the drive status (2) Connection of the common for the logic inputs depends on the positioning of the switch (Source, PLC, Sink) (3) Reference potentiometer SZ1RV1202 All terminals are located at the bottom of the drive. Install interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Switches (Factory Settings) Voltage/current selection for analog I/O (VIA and VIB) Voltage/current selection for analog I/O (FM) Selection of logic type (1) (2) negative logic positive logic Other Possible Wiring Diagrams 8 Logic Inputs According to the Position of the Logic Type Switch "Source" position "Sink" position "PLC" position with PLC transistor outputs (1) PLC (1) PLC 2-wire control F: R: (2) Forward Preset speed ATV 212 control terminals 3-wire control F: Forward R: Stop RES: Reverse (2) ATV 212 control terminals PTC probe (2) (3) ATV 212 control terminals Motor Analog Inputs Voltage analog inputs External +10 V (2) (4) ATV 212 control terminals Speed reference potentiometer 2.2 to 10 k (2) ATV 212 control terminals 9 Analog input configured for current: 0-20 mA, 4-20 mA, X-Y mA (2) (5) ATV 212 control terminals Source 0-20 mA, 4-20 mA, X-Y mA Analog input VIA configured as positive logic input ("Source" position) (2) ATV 212 control terminals Analog input VIA configured as negative logic input ("Sink" position) (2) 10 ATV 212 control terminals Product data sheet Performance Curves ATV212HD22N4S Derating Curves The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type (A, B or C). For intermediate temperatures (45C for example), interpolate between 2 curves. X Switching frequency 11