Performance/Functional Specifi cations
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➀
Input
Input Voltage Range:
Q12 Models 10-36 Volts (24V nominal)
D24 Models 18-36 Volts (24V nominal)
Q48 Models 18-75 Volts (48V nominal)
D48 Models 36-75 Volts (48V nominal)
Undervoltage Lockout:
Q12 Models 9 Volts
D24 Models 17 Volts
Q48 Models 17 Volts
D48 Models 34 Volts
Input Current See Ordering Guide
Input Filter Type ➁ Pi
Overvoltage Shutdown:
D24 and Q12 Models 40 Volts
D48 and Q48 Models 80 Volts
Reverse-Polarity Protection Yes (Instantaneous, 6A maximum)
On/Off Control (Pin 5) ➂ TTL high (or open) = on, low = off
Output
VOUT Accuracy (50% load) ±1%, maximum
Temperature Coeffi cient ±0.02% per °C
Ripple/Noise (20MHz BW) See Ordering Guide
Line/Load Regulation See Ordering Guide
Effi ciency See Ordering Guide
Isolation Voltage 1500Vdc, minimum
Isolation Capacitance 130pF
Current Limiting Continuous, auto-recovery
Overvoltage Protection Zener/transorb clamp, magnetic feedback
Dynamic Characteristics
Transient Response (50% load step) 200µsec max. to ±1.5% of fi nal value
Switching Frequency 165kHz (±10%)
Environmental
Operating Temperature (ambient):
Without Derating –40 to +50°C (model dependent)
With Derating to +100°C (See Derating Curves)
Maximum Case Temperature +100°C
Storage Temperature –40 to +105°C
Relative Humidity To 85°C /85% RH, non-condensing
Physical
Safety UL/cUL/EN/IEC 60950-1
Dimensions 2.04" x 3.04" x 0.55" (51.8 x 77.2 x 14mm)
Shielding 5-sided
Case Connection Pin 4
Case Material Aluminum, black anodized fi nish
with plastic header
Flammability Rating UL94V-0
Pin Material Gold-plated copper alloy with nickel
underplate
Weight 6 ounces (170 grams)
➀ These converters require a minimum 10% output loading to maintain specifi ed regulation.
Operation under no-load conditions will not damage these devices; however they may not
meet all listed specifi cations.
➁ Deleted.
➂ Applying voltage to the Control pin with no input power applied can damage the converter.
➃ Listed spec is for input-to-output. Input-to-case and output-to-case isolation is 1000Vdc min.
Input Voltage:
Q12/D24 Models 44 Volts
Q48/D48 Models 88 Volts
Input Reverse-Polarity Protection Current must be <6A. Brief
duration only. Fusing recommended.
Output Overvoltage Protection
5V Outputs 6.8 Volts, limited duration
12V Outputs 15 Volts, limited duration
15V Outputs 18 Volts, limited duration
Output Current Current limited. Max. current and
short-circuit duration are model
dependent.
Storage Temperature –40 to +105°C
Lead Temperature (soldering, 10 sec.) +300°C
These are stress ratings. Exposure of devices to greater than any of these
conditions may adversely affect long-term reliability. Proper operation under
conditions other than those listed in the Performance/Functional Specifi cations
Table is not implied.
Absolute Maximum Ratings
TECHNICAL NOTES
Floating Outputs
Since these are isolated DC/DC converters, their outputs are "fl oating." Us-
ers may ground either the Common (pin 8) for normal usage or the positive
side (+Output, pin 9) to effectively reverse the output polarity.
Filtering and Noise Reduction
All UMP 25-40 Watt DC/DC Converters achieve their rated ripple and noise
specifi cations without the use of external input/output capacitors. In critical
applications, input/output ripple and noise may be further reduced by install-
ing electrolytic capacitors across the input terminals and/or low-ESR tanta-
lum or electrolytic capacitors across the output terminals. The caps should
be located as close to the power converters as possible. Typical values are
listed in the tables below. In many applications, using values greater than
those listed will yield better results.
To Reduce Input Ripple
Q12/D24 Models 47µF, 50V
Q48/D48 Models 10µF, 100V
To Reduce Output Ripple
5V Outputs 47µF, 10V, Low ESR
12/15V Outputs 22µF, 20V, Low ESR
Input Fusing
Certain applications and/or safety agencies may require the installation of
fuses at the inputs of power conversion components. For DATEL UMP
DC/DC Converters, you should use slow-blow type fuses with values no
greater than the following:
V
IN Range Fuse Value
Q12 4A
D24 4A
Q48 3A
D48 2A
UMP Models
25-40W, Single Output, DC/DC Converters
MDC_UMP25-40W_B04 Page 3 of 9