Mechanical life (operations)
Breakdown voltage acc. to IEC/EN 61812
-1
2.5 kV /1 min / 1 mA / 50 Hz
Impulse voltage acc. to IEC/EN 60664
-
1, IEC/EN 61812
-1
0,7 A AC/DC
20 °C (0,5 A UL)
Maximum admissible current
Voltage breaking capacity
Maximum voltage drop at terminals
Electrical life (operations)
Mechanical life (operations)
Breakdown voltage acc. to
IEC/EN 60664
-
1, IEC 60255
-5
Volt-free contact
3-wire PNP output control option residual voltage : 0.4V whatever the timer power supply
IEC/EN 61812
-1
IEC/EN 61000
-6-1
IEC/EN 61000
-6-2
IEC/EN 61000
-6-3
IEC/EN 61000
-6-4
Temperature limits use (°C)
Temperature limits stored (°C)
Installation category
(acc. to IEC/EN 60664
-1) )
Creepage distance and clearance acc. to IEC/EN 60664
-1
Protection (IEC/EN 60529)
Degree of protection acc. to IEC/EN 60529 Front face
(except Tk2R1)
Vibration resistance
acc. to IEC/EN 60068
-2-6
Relative humidity
no condensation acc. to IEC/EN 60068
-
2-30
Electromagnetic compatibility
-
Immunity to electrostatic
discharges acc to IEC/EN 61000
-4-2
Level III (Air 8 KV / Contact 6 KV)
Immunity to radiated, radio
-frequency, electromagnetic
field acc. CEI/EN 61000
-4-3
Level III 10V/m (80 M Hz to 1 G Hz)
Immunity to rapid transient bursts acc. to IEC/EN 61000
-4-
4
Level III (direct 2kV / Capacitive coupling clamp 1 KV)
Immunity to shock waves on power supply acc. to IEC/EN
61000-4-5
Level III (2 KV / common mode 2 KV/residual current mode 1KV)
Immunity to radio frequency in common mode acc. to
IEC/EN 61000
-4-6
Level III (10V rms : 0.15 M Hz to 80 M Hz)
Immunity to voltage dips and breaks acc. to IEC/EN 61000
-
4-11
30 %/10 ms
60 %/100 ms >
95 %/5 s
Mains
-
borne and radiated emissions acc. to EN 55022
(CISPR22), EN55011 (CISPR11)
Fixing : Symmetrical DIN rail
Connection capacity - without ferrule
Connection capacity - with ferrule
Spring terminals, 2 terminals per connection point
-
flexible wire
Spring terminals, 2 terminals per connection point
-
rigid
wire
State displayed by 2 LEDs
- Flashing green when on
-
Relay LED yellow during timing
Green LED operation indicator
Pulsing :
-
Timer on, no timing in process
Permanently lit :
- Relay waiting, no timing in process
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
22/10/2012 www.crouzet.com