Ultrasonic Sensors 940 Series
Compact 18 mm Diameter Digital
B82 Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada
FEATURES
1Sensing distance up to 1,5 meters
118 mm diameter housing
1IP 67 sealing
1High output current
1High power transducer
1Microprocessor controlled
ORDER GUIDE
Sensor Sensing Digital
Package Range* Output Termination Catalog
Style mm (in.) Listing
18 mm dia. 200 - 1500 PNP, N.O. Cable 940-F4Y-2D-001-180E
PBTB Plastic (7.87 - 59.05) NPN, N.O. Cable 940-F4Y-2D-002-180E
PNP, N.O. Connector cable 940-F4X-2D-001-180E
NPN, N.O. Connector cable 940-F4X-2D-002-180E
150 - 700 PNP, N.O. Cable 940-F4Y-2D-001-300E
(5.9 - 27.5) NPN, N.O. Cable 940-F4Y-2D-002-300E
PNP, N.O. Connector cable 940-F4X-2D-001-300E
NPN, N.O. Connector cable 940-F4X-2D-002-300E
* Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam.
SPECIFICATIONS
Catalog Listings 940-F4Y-2D-001-180E 940-F4Y-2D-001-300E
940-F4Y-2D-002-180E 940-F4Y-2D-002-300E
940-F4X-2D-001-180E 940-F4X-2D-001-300E
940-F4X-2D-002-180E 940-F4X-2D-002-300E
Max. Sensing Distance 1500 mm (59.05 in.) 700 mm (27.5 in.)
Min. Sensing Distance 200 mm (7.87 in.) 150 mm (5.91 in.)
Beam Angle 8°8°
POWER SUPPLY
Supply Voltage 19 - 30 VDC
Supply Current <25 mA without load <35 mA without load
Circuit Protection Reverse polarity
OUTPUT CHARACTERISTICS
Load Current 0 - 500 mA
Switching Frequency 8 Hz 25 Hz
Hysteresis `2% of setpoint `2.5% of setpoint
Repeatability ±1 mm
Setpoint Adjustment 4-turn potentiometer
Circuit Protection Short circuit
ENVIRONMENTAL
Operating Temperature –15 to 70°C (5 to 158°F)
Storage Temperature –25 to 85°C (–13 to 185°F)
Sealing IP 67
SPECIAL FEATURES
Hold Input Stops transmission and reception when input is connected to 0 VDC. Last output will be stored until input is disconnected
Synchronization Input Avoids mutual interference from several sensors by interconnecting the hold input from each sensor.
LED Indicator Illuminates when sensor detects target