MVAB120 Series
120W 2" x 4" AC-DC Power Supply Converter
MVAB120.A13 Page 2 of 7
www.murata-ps.com/support
ENVIRONMENTAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Storage Temperature Range -40 85
°C
Operating Temperature Range
Full load -10 50
50% load -10 70
Start up -20
Operating Humidity Non-condensing 10 95 %
Operating Altitude Without derating -200 3000 m
MTBF Telcordia SR-332 M1C3 25°C 1M Hours
Shock
Operating, IEC60068-2-27, half-sine 5G, 6ms, 3 times per face,
6 faces Complies
Non-operating, IEC60068-2-27, half-sine, 30G, 18ms, 3 times
per face, 6 faces Complies
Vibration
Operating, IEC60068-2-6, 1.0G, 10-150Hz, 10minutes per axis,
on all 3 axes Complies
Non-operating, IEC60068-2-6, 2.0G, 10-150Hz, 10minutes per
axis, on all 3 axes Complies
Safety
IEC60950-1:2005 (2nd Edition); Am1:2009
UL60950-1 2nd Edition,2011-12-19, CSA C22.2 No. 60950-1-07, 2nd Edition,2011-12
EN60950-1:2006 + A11:2009 + A1:2010 + A12:2011
IEC60601-1:2005 + CORR.1(2006) + CORR.2(2007)
ANSI/AAMI ES60601-1 (2005+C1:09 + A2:10), CSA-C22.2 No. 60601-1(2008), MOPP
CE Marking per LVD
Warranty 2 years
Outside Dimensions 2.0" x 4.0" x 1.35" (50.8mm x 101.6mm x 34.3mm); 2.0" x 4.0" x 1.41" (50.8mm x 101.6mm x 35.8mm) for medical version
Weight MVAB120-12/-01 0.34lbs (155g) typical
MVAB120-24/-01, MVAB120-28/-01, MVAB120-48/-01 0.36lbs (162g) typical
PROTECTION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Overvoltage Protection Latching 110 160 %V1
Overcurrent Protection Hiccup mode 105 150 %Amax
Overtemperature Protection Auto recovery Complies
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation
Primary to Earth Ground (1MOOP) 1500 Vac
Primary to Secondary (2MOOP or 1 MOPP) 3000
Secondary to Earth Ground 500 Vdc
Leakage Current (under normal conditions) 264Vac, 60Hz, 25°C 500 μA
EMISSIONS AND IMMUNITY
Characteristic Standard Compliance
Input Current Harmonics IEC/EN 61000-3-2 Class A
Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Complies
Conducted Emissions EN 55022 Class B, Class A (at class II equipment)
FCC Part 15 Class B, Class A (at class II equipment)
ESD Immunity IEC/EN 61000-4-2 Level 4, Criterion A
Radiated Field Immunity IEC/EN 61000-4-3 Level 2, Criterion A
Electrical Fast Transient Immunity IEC/EN 61000-4-4 Level 3, Criterion A
Surge Immunity IEC/EN 61000-4-5 Level 3, Criterion A
RF Conducted Immunity IEC/EN 61000-4-6 Level 2, Criterion A
Magnetic Field Immunity IEC/EN 61000-4-8 Level 1, Criterion A
Voltage dips,interruptions IEC/EN 61000-4-11 Level 3, Criterion B