HAMMOND
MANUFACTURINGTM
ENCLOSURES
TOOL BOX
BU10051
2000 WALLMOUNT- SERIES
ASSEMBLY INSTRUCTIONS FOR 2P, 2R & 2S SERIES
REV. C
PAGE 1 OF 1
GROUND HARDWARE KIT
MOUNTING FOOT (VERTICAL)
INNER PANEL ASSEMBLY
HOLE PLUG ASSEMBLY
1
3
12
12
ENCLOSURE
DOOR
RDHD SCREW
1/4 - 20 BRASS
1/4 - 20
KEP NUT
3
1/4 - 20 X 5/8 LG
GRD. STUD
1/4 - 20
HEX NUT
GROUND STRAP
(NOT INCLUDED)
ENCLOSURE
MOUNTING FOOT
3/8 - 16 X 3/4
STUD
INNER PANEL
3/8 FLAT WASHER
1/4 Slot Head
Screw Driver 3/8, 7/16, 9/16" Socket
Wrench or Driver
PART # QTY. DESCRIPTION
1 4 HEX NUT 3/8 - 16
2 4 3/8 SEALING WASHER
3 4 HEX HEAD BOLT 3/8 - 16 X 3/4
NOTES:
-WHEN MOUNTING THE ENCLOSURE USING INTERNAL HOLES, MAKE
SURE THE SURFACE IS FLAT OR SHIM THE SURFACE TO FLATTEN . USE
A HEX HEAD BOLT (PART 1) AND A SEALING WASHER (PART 2) (RUBBER
SIDE IN CONTACT WITH THE ENCLOSURE).
-TORQUE 3/8 - 16 TO 180" LBS. AND 1/4 - 20 TO 50" LBS.
NOTE:
- TO MAINTAIN A NEMA 4 RATING,
PLUG HOLES AS SHOWN, IF THE FOUR
MOUTING HOLES ARE NOT REQUIRED.